Descripción
Sen FHSD8210-09 Laser Suction Smoke Detector
The eLaserSenseHSSD2 sensor is designed to provide very high smoke detection sensitivity, ensuring the eest warning of a fire with the minimum rate of alarms.
ClassiFire perceptual artificial intelligence ensures that the detector operates at all timeswith optimal sensitivity to the protected environment, without the need for complex configuration. This means that the product will be configured to offer high sensitivity in a computer room or decrease its sensitivity in a smoke-filled area.
Upgradeable fault and fire-free outputs are available for remote monitoring of detector status.
Where can we install the Sen FHSD8210-09 Laser Suction Smoke Detector?
• Data storage units
• Cells
• Plant rooms
• Air conditioning units
• Rack equipment
• Computer rooms
• Air duct protection
• Heritage protection
• Critical teams
• Anti-tobacco applications
• Engine rooms
Available options
• APIC addressable cards™ available for Ziton protocol
• “Command Module” repeater available for central system monitoring
• SenseNet compatible – up to 127 detectors per loop
• Remote displays
• Suitable for MatrixScan, a patented software that provides virtual addressable detection – for example, 10 physical detectors can provide up to 45 unique addressable sampling points.
Features of the Sen FHSD8210-09 Laser Suction Smoke Detector
- High sensitivity provided by a detection in a laser camera
- Combined sampling tubes up to 200m in length (with calm air)
- ClassiFire ® unique perceptual artificial intelligence system that dynamically adjusts detector operating parameters, adjusting to daily changes in protected environment and dust contamination of the filtering system
- Unwanted dust alarms are avoided by patented LDD 3D3 laser dirt discrimination and by the removal system
- RS485 communication for networks and remote communications
Operating voltage | 21.6 to 26.4 VDC |
Current consumption | 450 mA at fan speed 8 |
Detection principle | Mass detection by laser light scattering and particle evaluation |
Particle sensitivity range | 0.003 μ up to 10 μ |
Physical dimensions | 427 x 372 x 95 mm (width x height x depth) |
Net weight | 5.2 kilograms |
Color | Cream |
Cable inputs | 6 x M20 |
material | Sheet steel cover |
Operating temperature | -10 to +60oC (EN54-20) |
Relative humidity | 0 to 90% non-condensing |
Environment | Inside |
IP rating | IP40 |
Certification | EN54-20 |
Measuring range (% Obs/m) | 0.0015% to 25% |
Alarm levels | 4 (Aux, pre-alarm, alarm and alarm 2) |
Sinks | 4 |
Length | Maximum single stroke of 100 m (50 m in moving air) |
Diameter | 27 mm outer diameter |
Holes | up to 100 holes |
Tired | 1 (optional) |
Standard | 5 – Pre-alarm, Alarm, Alarm2, Aux Alarm (n/o) and Fault (n/c) |
Classification | 500 mA to 30 V |
Expansion | Optional input and relay card |
Indicators | Led |