Conventional optical smoke detector. ID100

16,02 + IVA

Conventional optical smoke detector ID100 iris series,Guardal / Inim electronics. For conventional fire plant. Baseless

SKU DEL PRODUCTO: ID100 Categorías , Etiqueta

*Los productos no incluyen gastos de transporte y los precios son exclusivos online.

Descripción

https://www.serior.com/detector-optico-de-humos-id100

Iris Series

Conventional IRIS series detectors are easy to install and have a number of technical characteristics that equate them to more sophisticated models that until recently only existed in analogue systems. The result is that detectors can offer great operational stability and are virtually immune to false alarms.

The detectors have a technology called Versa ++ that allows you to adjust the detector individually depending on the environment to which it is exposed. In addition, if you connect the EITK1000 programming kit, you can get deeper analysis of the detector in real time and make adjustments to it.

Each detector has a memory that shows smoke and temperature levels just before the last alarm.

Conventional optical smoke detector. ID100

The ID100 optical smoke detector,with Tyndall effect of diffusion of light, causes an alarm signal in case of fires, in this case, by the detection of fumes.

The detector has a sensitivity settingd using the EDRV1000, and is factory set to 0.15dB/m. The adjustment range is 0.08 – 0.10 – 0.12 – 0.15 dB/m depending on the area we want to protect.

We can perform a real-time diagnosis of the values that the detection camera gives us and has a memory of the last alarm.

UNE EN-54 Part 7 Certificate.

In addition, we can highlight the following features:

  • It has a sealed chamber and a protective mesh that protects it from insects.
  • Status indication LED. In permanent red will be alarm,in green color and slow flicker will be resting state,and the fast green flicker will be detector failure.
  • Remote output.
  • Adjustable smoke sensitivity and temperature with kit EDRV1000.
  • Metal sheet that bridges the base, allowing the detector to be disassembled without creating a fault in the fire plant.

 

Voltage
10 – 30 V
Consumption at rest
90 A
Consumption in alarm
Max 40 mA
Sensitivity 0.08 – 0.10- 0.12- 0.15 dB/m
Operating temperature
-5oC + 40oC
Height (based)
46 mm
Diameter
110 mm
Weight (based)
160g
Weight (without base) 90g

Información adicional

Tipo detección

Optical smoke

Sistema

Conventional

Fabricante

INIM ELECTRONICS